Enabling and Removing PNC Duplication<br />

To Enable PNC Duplication<br />

ATM PNC-DUP (ATM PNC Duplication)<br />

To enable PNC duplication, perform the following sequence of steps:<br />

1. Enable administration of PNC-DUP on the change system-parameters<br />

customer-options screen.<br />

2. Fully administer duplicate ATM PNC connectivity. Verify by list atm pnc. Or for IP<br />

duplication, go to step three.<br />

3. Fully administer IPSI duplication (ipserver-interface duplication). Verify by using<br />

list ipserver-interface.<br />

4. Activate PNC-DUP through the change system-parameters duplication screen.<br />

This is not allowed if any component of either PNC (A or B) is busied out.<br />

5. The system must insert all connectivity-related components for both standby and active<br />

PNC, a process that takes up to 5 minutes, depending upon circuit pack insertion. The<br />

process finishes when the first terminal login prompt appears.<br />

6. The PNC-DUP initialization anti-thrashing timer must expire (this occurs 5 minutes after<br />

completion of board insertion, PNC interchange, or system reset of level 2 or higher).<br />

To Disable PNC Duplication<br />

To disable PNC duplication perform the following sequence of steps:<br />

1. Verify that the A-PNC is active. A forced interchange may be required. See reset pnc.<br />

2. Busyout the standby PNC (B-PNC).<br />

3. Turn off the system parameter for PNC-DUP through change system-parameters<br />

duplication.<br />

4. Remove the B-PNC connectivity by removing the Board Locations on the change fiber<br />

screen for ATM PNC.<br />

5. Remove the B-PNC circuit packs (ATM-EI boards). Enter change circuit-pack<br />

location.<br />

6. Disable administration of PNC duplication on the change system-parameters<br />

customer-options screen by changing the PNC Duplication field to n.<br />

Notes:<br />

● Alterations to PNC that involve only the addition of connectivity can be done with<br />

PNC-DUP operational.<br />

● Alterations requiring the removal of connectivity must be done with PNC-DUP removed.<br />

● PNC-DUP must be removed and translations should be saved before making any<br />

hardware changes.<br />