Communication Manager Maintenance Object Repair Procedures<br />

The red and green LEDs have the traditional use where red means an alarm condition and<br />

green indicates that maintenance testing is in progress. The red and green LED is also turned<br />

on during circuit pack initialization by firmware. When the control link to the circuit pack is lost,<br />

firmware controls the red LED to indicate an alarm condition.<br />

The amber LED indicates the state of the:<br />

● Physical fiber interface<br />

● Fiber channel (link to EI or SNI)<br />

● DS1 control channel (link to opposite DS1 converter board)<br />

● <strong>Server</strong> communications link<br />

in the following manner and descending order of priority. (The amber LED stays lit longer as the<br />

DS1 converter complex approaches full operation.)<br />

1. If the fiber is out of frame or is in a loss-of-signal condition, the amber LED will flicker at a<br />

5-Hz rate (on for 0.1 second, off for 0.1 second).<br />

2. If the fiber channel is down (DS1 Converter circuit pack/fiber endpoint communications), the<br />

amber LED will flash at a 1-Hz rate (on for ½ second, off for ½ second).<br />

3. If the DS1 control channel is down between the two DS1 converters in the DS1 converter<br />

complex, the amber LED will pulse at a 1/2-Hz rate (on for 1 second, off for 1 second).<br />

4. If the server communications link is down, the amber LED will wink off every 2 seconds for<br />

200 msec (2 seconds on, 0.2 second off).<br />

5. If all is well with the Fiber Interface and every communications channel, the amber LED will<br />

remain on continuously in a standard-, duplex-, or high-reliability system. In a<br />

critical-reliability system (duplicated PNC):<br />

- An active DS1 converter circuit pack’s amber LED remains on continuously.<br />

- A standby DS1 converter circuit pack’s amber LED remains off.<br />

The LED will then be under software control.<br />

The bottom four green LEDs on the TN574 DS1 converter board are under hardware control.<br />

The four green LEDs indicate, for each DS1 converter facility, whether a receive signal is<br />

present for the DS1 facility.<br />

The next four LEDs on the TN1654 DS1 converter board are labeled STATUS LEDs and are for<br />

future use. These LEDs will not be lit.<br />

The bottom four LEDs on the TN1654 board are labeled SPAN LEDs. These LEDs are under<br />

firmware control. If the facility is not administered, then the LED is not lit. The LED is lit amber if<br />

the facility is running alarm free. If the facility is detecting either a red alarm (loss-of-signal or<br />

loss-of-frame), a yellow alarm (remote frame alarm) or a blue alarm (AIS signal) then the LED is<br />

lit red. The SPAN SELECT Switch on the TN1654 faceplate is for future use. Pushing the switch<br />

will have no affect on the board.<br />