Table 388: Port Diagnostic Test (#35) 5 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Port Diagnostic Test (#35)<br />

FAIL ALARM-PT: The port’s battery feed chip is unable to supply sufficient<br />

power to sense the external device alarm. This may occur when the<br />

test is performed at the same time that the external device contact<br />

closure occurs.<br />

1. Enter test external-device-alarm port location to<br />

determine whether the port is reporting an EXT-DEV failure. Wait<br />

until the port has no EXT-DEV failures before retesting.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

ANL-16-L, ANL-LINE, AN-LN-PT, MET-LINE, RANL-STA: The port's<br />

battery feed chip is unable to supply sufficient power to the terminal<br />

equipment. This may occur when the test is performed at the same<br />

time the terminal equipment goes off-hook.<br />

1. Enter display port location to determine the station<br />

extension of the port.<br />

2. Enter status station to determine the service state of the port.<br />

If the port is in use, wait until it is idle before testing.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

4. If the test continues to fail, determine whether the customer is<br />

experiencing problems on this line. Replace the circuit pack or<br />

media module only if the customer is experiencing problems.<br />

5 of 6<br />

Communication Manager Release 5.0 Issue 4 January 2008 1487