Table 464: Neon Test (#220) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

140AY Channel Sanity Inquiry Test (#222)<br />

140AY Channel Sanity Inquiry Test (#222)<br />

FAIL The test failed because no neon current was detected.<br />

1. Determine if there is a TN755 or TN752 power unit circuit pack<br />

installed in the same carrier as the analog line circuit pack that failed<br />

the test. Look for the failure of test 220 on other analog circuit packs<br />

in the carrier. If test 220 fails on the other circuit packs, replace the<br />

TN755 or TN752 power unit circuit pack.<br />

2. Retry the command again.<br />

3. If the test continues to fail, replace the circuit pack.<br />

PASS Neon current is detected.<br />

Any NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

3 of 3<br />

This test queries the Angel to determine the status for a particular channel. If a channel is<br />

insane, announcements cannot be played back on that channel. This test runs on This test runs<br />

on ANN-PT (Announcement Port).<br />

Table 465: 140AY Channel Sanity Inquiry Test (#222) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1659