Demand test descriptions and error codes<br />

CARR-POW (Carrier Power Supply)<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Battery and Power Supply Query Test (#5) X X ND<br />

AC Power Query Test (#78)) X X ND<br />

OLS/Power Unit Query Test (#127) (Carrier E) X X ND<br />

OLS/Power Unit Query Test (#127) (Carrier D) X X ND<br />

OLS/Power Unit Query Test (#127) (Carrier A) X X ND<br />

OLS/Power Unit Query Test (#127) (Carrier B) X X ND<br />

OLS/Power Unit Query Test (#127) (Carrier C) X X ND<br />

OLS Recycle Test (#126) D<br />

Emergency Transfer Query Test (#124) X X ND<br />

Cabinet Temperature Query Test (#122) X X ND<br />

External Device Alarm Query Test (#120) X X ND<br />

Ring Generator Initialization Test (#117) X X ND<br />

Ring Generator Query Test (#118) X X ND<br />

1. D = Destructive; ND = Nondestructive<br />