Table 234: HYB-LINE Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

1 (a) 40987 WRN OFF<br />

15 (b) Any Analog Line Audits<br />

test (#61)<br />

HYB-LINE (Hybrid Line)<br />

18 (c) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

130 (d) WRN ON test port location<br />

257 (e) 40988 MIN<br />

WRN<br />

OFF<br />

513 (f) 40965 Analog Line Audits<br />

test (#61)<br />

WRN OFF test port location r 4<br />

769 (g) Remote Digital<br />

Looparound (#59)<br />

WRN OFF test port location r 3<br />

1025 Hybrid Circuit &<br />

Conf. Circuit (#57)<br />

1281(g) (h) Local Digital<br />

Looparound (#58)<br />

MIN<br />

WRN<br />

1537 (h) (i) 40968 WRN OFF<br />

1793 NPE Crosstalk<br />

Test (#6)<br />

2049 (i) (j) 32770<br />

2049 (j) 40967<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

ON test port location l r 3<br />

WRN ON test port location l r 3<br />

MIN ON test port location l r<br />

WRN2 1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate<br />

test’s description, and follow its recommended procedures.<br />

2. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options<br />

command.<br />

2 of 2<br />

Notes:<br />

a. Error Type 1: The data link between the port and the terminal is not operational. (An<br />

off-board problem was detected by port circuit). Verify that the Hybrid set is connected and<br />

that the Electronic Power Feed (EPF) test passes. If data transmission problems are<br />

experienced, check for defective wiring or a defective voice terminal, or move terminal<br />

closer to the switch (reduce the length of the wiring between the terminal and the switch). If<br />

the problem persists, replace the circuit pack. Once the problem has been resolved, the<br />

alarm will be retired after a predetermined delay.<br />

Communication Manager Release 5.0 Issue 4 January 2008 875