DAT-LINE (Data Line Port)<br />

DAT-LINE (Data Line Port)<br />

The TN726 Data Line circuit pack has eight ports, each of which supports an RS-232 interface<br />

to asynchronous CPE (customer-premises equipment). Each of these ports and the equipment<br />

connected to it constitute a data line.<br />

For DT-LN-BD (Data Line circuit pack) errors, see XXX-BD (Common Port Circuit Pack/Media<br />

Module). Check circuit pack-level errors first since the usability of the ports depend on the<br />

health of the circuit pack.<br />

Enter add data-module to administer data line ports at the terminal. The data module type is<br />

data-line. The list data-module command shows every administered data module in the<br />

system.<br />

The TN750 Announcement circuit pack has one data line-type port on it. This data line port is<br />

used for saving and restoring announcements. This data line port is not supported on the S8500<br />

and S8700-series servers. For a description of and repair instructions for the TN750, see<br />

ANL-BD (Analog Line Circuit Pack).<br />

Note: If<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

DAT-LINE MIN<br />

WRN<br />

Note:<br />

the tests for the data line port in question pass, and user-reported complaints<br />

persist, there is probably an external problem. Test the ADU (asynchronous data<br />

unit), using the procedures in Multiple Asynchronous Data Unit User Manual,<br />

555-401-702. If the ADU appears to be working properly, check the external<br />

wiring, then check the equipment.<br />

Error log entries and recommended actions<br />

Table 175: DAT-LINE Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

test port location l Data Line port<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test port location<br />

1 Digital<br />

Looparound test<br />

(#171)<br />

MIN ON test port location r 2<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 671