Communication Manager Maintenance Object Repair Procedures<br />

Table 385: Digital Station Lamp Update Test (#16) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

3 ABORT Station may be in ready-for-service or out-of-service state.<br />

1. Enter status station to verify the state of the station.<br />

2. Make sure the terminal is connected.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this test are not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the station extension<br />

or attendant number of the port.<br />

2. Enter status station or status attendant to determine the<br />

service state of the port. If the port is in use, wait until it is idle before<br />

testing. Attendants are always in use (off-hook) if the handset is<br />

plugged in and the port is not busied out.<br />

3. If the port status is idle, retry the command at 1-minute intervals up<br />

to 5 times.<br />

1392 ABORT This port is a TTI port. The test does not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port (the port<br />

is a TTI port) or list config (a “t” is displayed for the port).<br />

2. If either list config or display port indicates that the port is<br />

not a TTI port, escalate the problem. If both commands indicate that<br />

the port is a TTI port, the abort is correct, and no action is necessary.<br />

FAIL Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

PASS The message to light every station lamp was successfully sent to the<br />

port.<br />

1. Observe the station lamps being lit when running the test. If all lamps<br />

do not light, the other Digital Line test results may indicate related<br />

problems that do not allow the lamps to light.<br />

2. Investigate troubles by using other Digital Line port tests, and by<br />

examining the station, wiring, and connections.<br />

1474 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s