Table 489: Expansion Interface Reset Test (#336) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

PN Maintenance Circuit Pack Serial Link Test (#337)<br />

PASS The EI was successfully reset. Release the EI circuit pack from the<br />

busyout state by using release board location.<br />

See NO BOARD for repair procedures.<br />

PN Maintenance Circuit Pack Serial Link Test (#337)<br />

This test is destructive.<br />

This test checks the serial link from the standby EI or standby IPSI circuit pack to the PN’s<br />

Maintenance circuit pack. If there is no standby link or the standby link is down at the time of the<br />

test, this test aborts.<br />

Note:<br />

Note: The status of the link changes to “down” when the standby EI or standby IPSI<br />

circuit pack begins initialization tests (for example, after being reset). The link<br />

status updates at the conclusion of these tests.<br />

This test runs on MAINT (PN Maintenance Circuit Pack).<br />

Table 490: PN Maintenance Circuit Pack Serial Link Test (#337) 1 of 2<br />

Error<br />

Code<br />

1000<br />

2029<br />

2500<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required for this test are not available.<br />

Internal system error.<br />

Internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

3 of 3<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1715