Communication Manager Maintenance Object Repair Procedures<br />

This creates a hierarchy where the master PN receives timing from the public network, and<br />

every other PN derives its timing from the master through the CSS. See Figure 109: Traditional<br />

Sync Operation.<br />

Figure 109: Traditional Sync Operation<br />

Public<br />

Network<br />

Typically, a pair of interfaces from the public network are configured — one as a primary and<br />

one as a secondary. The IPSI/Tone-Clock in the Master PN can:<br />

● Lock onto either interface<br />

● Switch between them in the event of a failure<br />

In the event of a dual failure, the Tone-Clock in the master PN can generate its own timing and<br />

keep every PN synchronized. However, these PNs would not be synchronized with any other<br />

public-network interfaces that exist in any of the PNs.<br />

When a center stage is implemented via an ATM network, it is possible to obtain timing from the<br />

ATM network. For more information, See ATM-SYNC (ATM Synchronization).<br />

S8700-series IP-PNC<br />

Primary<br />

Secondary<br />

Master<br />

PN<br />

S8700-series IP-PNC <strong>Server</strong> Sync Operation<br />

Center<br />

Stage<br />

Switch<br />

For an S8700 IP-PNC system, its port networks (PNs) are connected via the customer’s IP<br />

network. This network cannot be used to transmit timing information between the PNs. The<br />

complete set of PNs need not be synchronized with each other. Inter-PN bearer traffic is carried<br />

as VOIP, while the Media Processors’ internal jitter buffers deal with differences in transmission<br />

rates.<br />

Synchronization is needed for a PN with a public-network digital interface. Each PN with a DS1<br />

or trunk-side BRI interface must be synchronized with an external timing source to prevent slips<br />

1254 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

Slave<br />

PN<br />

Slave<br />

PN<br />

Slave<br />

PN