● EMG-XFER (Emergency Transfer)<br />

● EXT-DEV (External Device Alarm)<br />

● POWER<br />

● POW-SUP (Power Supply)<br />

● RING-GEN (Analog Ring Generator)<br />

● RMC-ENV (Power/Fan Sensors)<br />

● SER-BUS (Serial Communication Bus)<br />

Table 423: Ring Generator Query Test (#118) 1 of 4<br />

Error<br />

Code<br />

1<br />

1000<br />

1001<br />

1003<br />

1115<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

Ring Generator Query Test (#118)<br />

ABORT Could not seize the resources to run the test. Other maintenance is<br />

running on the active Tone-Clock circuit pack.<br />

1. Wait for the green LED on the active Tone-Clock circuit pack to go<br />

out.<br />

2. Enter status port-network to determine the active Tone-Clock<br />

circuit pack.<br />

3. Rerun the test. If the test aborts again, see TDM-CLK (TDM Bus<br />

Clock).<br />

2000 ABORT Response from the test was not received within the time allowed.<br />

1. Look for TDM-CLK (TDM Bus Clock) errors and alarms. Resolve<br />

every Tone-Clock problem first.<br />

2. Rerun the test.<br />

1 of 4<br />

Communication Manager Release 5.0 Issue 4 January 2008 1567