Communication Manager Maintenance Object Repair Procedures<br />

Table 557: Active-Standby Peer Link Test (#888) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

NO<br />

BOARD<br />

Description / Recommendation<br />

The IPSI circuit pack’s Packet Interface module is assigned but is not<br />

detected as physically present.<br />

1. If the IPSI circuit pack is present, replace it.<br />

2. If not, insert a TN2312AP IPSI circuit pack in the assigned slot, and<br />

rerun the test.<br />

Packet Interface Reset Test (#889)<br />

The reset action initializes the Packet Interface firmware on the IPSI circuit pack and runs a<br />

comprehensive set of diagnostic tests.<br />

The demand reset action aborts if the specified IPSI circuit pack’s Packet Interface module is in<br />

the active in-service state.<br />

An IPSI circuit pack’s Packet Interface module is put in the out-of-service state automatically if it<br />

resets 3 times by background maintenance within the last 15 minutes, independent of the<br />

results of the reset action.<br />

If the Packet Interface module is on the standby IPSI (S8700-series Fiber-PNC: and this is a highor<br />

critical-reliability system), the demand reset action runs, independent of the service state.<br />

This test runs on PKT-INT (Packet Interface).<br />

Table 558: Packet Interface Reset Test (#889) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1888 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

3 of 3<br />

1334 ABORT The Packet Interface modules’s command queue is full. This should be<br />

a temporary condition caused by a high rate of commands being sent to<br />

a Packet Interface module. Continued operation with a full command<br />

queue causes a system WARM restart that could escalate to more<br />

severe restart levels.<br />

1. Retry the command at 10 second intervals up to 5 times.<br />