Table 152: AUX-TRK Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

769(c) 57482<br />

Associated Test Alarm<br />

Level<br />

257 Hybrid/Conference MIN<br />

WRN 1<br />

Looparound<br />

Conference test<br />

(#33)<br />

513 NPE Crosstalk Test<br />

(#6)<br />

1025 Auxiliary Trunk<br />

Diagnostic Test<br />

(#114)<br />

MIN<br />

WRN 2<br />

On/Off<br />

Board<br />

AUX-TRK (Auxiliary Trunk)<br />

Recommended Action<br />

ON test port location l r 3<br />

ON test port location l r 3<br />

WRN ON test port location r 3<br />

1. Major or Minor alarms may be downgraded to Warning alarms based on the values used in set options.<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port if one is<br />

available until the circuit pack can be replaced.<br />

c. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling lead, which is an<br />

off-board error. This error should only occur with loudspeaker paging. If the trunk is being<br />

used for another application, check that the administration is correct. Otherwise, check the<br />

wiring to the external equipment connected to the Auxiliary Trunk and check the external<br />

equipment.<br />

d. Error Type 15: software audit error that does not indicate any hardware malfunction. Run<br />

short test sequence, and investigate associated errors.<br />

e. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the error, reseat or replace the circuit pack.<br />