Red Alarm Inquiry Test (#140)<br />

Since PLB is a condition rendering all DS0 channels unavailable for signaling or bearer traffic,<br />

the system treats this the same as a Blue Alarm.<br />

Table 433: Blue Alarm Inquiry Test (#139)<br />

Error<br />

Code<br />

Test Description/ Recommendation<br />

Result<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals for a maximum of 5 times.<br />

2000 ABORT Response to the test was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display errors on the SAT.<br />

2. Check for Error Type 1538 for this DS1 board. If Error Type 1538<br />

appears in the error log for this board, see Hyperactive DS1/UDS1<br />

Interface Circuit Pack/Media Module for the repair procedures.<br />

Otherwise, retry the test at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals for a maximum of 5 times.<br />

FAIL The remote DS1 endpoint is out-of-service.<br />

1 FAIL A Line Loopback Alarm (LLB) was detected.<br />

2 FAIL A Payload Loopback Alarm (PLB) was detected.<br />

1. If the DS1/UDS1 circuit pack or media module connects to a T1<br />

network facility or to another switch, see T1 Network Facility<br />

Procedures<br />

PASS<br />

2. If the DS1/UDS1 circuit pack or media module connects to a<br />

line-side terminating device such as a PRI terminal adapter, see<br />

Line-side Terminating Device Procedures<br />

Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line<br />

Loopback alarm nor a Payload Loopback Alarm was detected.<br />

0 NO<br />

BOARD<br />

See NO BOARD for the repair procedures.<br />

Red Alarm Inquiry Test (#140)<br />

A DS1/UDS1 Interface circuit pack or DS1 Interface Media Module raises a Red alarm when the<br />

framing pattern of the incoming DS1 bit stream has been lost. The Red Alarm Inquiry test<br />

checks the framing status of a DS1 board.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1603