Table 355: TDM-CLK Error Log Entries 2 of 2<br />

Error<br />

Type<br />

769 (g) Any Clock Circuit Status<br />

inquiry (#148)<br />

1025 (h) Any Clock Slip inquiry<br />

(#149)<br />

1281<br />

1282 (i)<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

Any MIN OFF<br />

1537 Any Clock PPM inquiry<br />

(#150)<br />

2049 (j) Any Standby Reference<br />

Health Check test<br />

(#651)<br />

On/Off<br />

Board 1<br />

2305 (k) 0 WRN OFF<br />

Recommended Action<br />

TDM-CLK (TDM Bus Clock)<br />

MAJ‡ ON test tone-clock location r 10<br />

test tone-clock location<br />

test tone-clock location<br />

MAJ 2 ON test tone-clock location<br />

1. As a general rule, any on-board errors against the TDM Bus Clock should be resolved before pursuing any<br />

other errors against PNC components. Off-board clock errors may be caused by other board errors, and<br />

should be addressed after on-board errors have been resolved.<br />

2. Major or Minor alarms on this MO may have been downgraded to Warning based on the values in set<br />

options.<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1: the IPSI or Tone-Clock circuit pack may have a clock at the edge of its<br />

specified frequency. This can cause Expansion Interface circuit packs and SNI circuit packs<br />

to go out-of-frame or report no-neighbor conditions. This can is turn cause EPNs,<br />

Expansion Archangel Links (EALs), Remote Neighbor Links (RNLs), and/or Local Neighbor<br />

Links (LNLs) to go down. When this error is alarmed, the Clock Health Inquiry test (#46) will<br />

fail with an Error Code of 1.<br />

1. Replace the IPSI or Tone-Clock circuit pack identified in the error log. See Replacing the<br />

IPSI or Tone-Clock Circuit Pack.<br />

c. Error Type 18: the indicated Tone-Clock circuit has been made unavailable using busyout<br />

tone-clock location. It only applies to systems with the high- or critical-reliability<br />

option administered, because only a standby Tone-Clock circuit may be made busy by that<br />

command. To resolve this error, execute release tone-clock location for the<br />

alarmed circuit pack.<br />

d. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the error, reinsert or replace the circuit pack.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1325

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!