UDS1-BD (UDS1 Interface Circuit Pack)<br />

E1 synchronization splitter not expected: The 402A or 403A E1 synchronization splitter<br />

is physically connected to the UDS1 board on the back of the port carrier, but the E1<br />

Sync-Splitter field on the add ds1 screen is not set to y.<br />

If the 402A or 403A E1 synchronization splitter is to be used, use change ds1 to set the<br />

E1 Sync-Splitter field to y. Otherwise, physically remove the 402A or 403A E1<br />

synchronization splitter from the back of the port carrier.<br />

l. Error Type 1302: DS1 configuration error. Attempting to use the 120A1 CSU module with a<br />

UDS1 circuit pack that is configured for 32-channel (2.048-Mbps) operation. The CSU<br />

module only works with a DS1 board configured for 24-channel (1.544-Mbps) operation in<br />

the United States of America.<br />

m. Error Type 1303: DS1 circuit pack suffix incorrect for CSU module/T1 sync splitter or for E1<br />

synchronization splitter.<br />

DS1 circuit pack suffix incorrect for CSU module/T1 sync splitter: The Near-End CSU<br />

Type field on the add ds1 screen is set to integrated but the DS1 circuit pack is not a<br />

TN464F or higher suffix UDS1 board.<br />

If the 120A1 CSU module or the 401A T1 sync splitter is to be used, remove the circuit pack<br />

and replace it with a TN464F or higher suffix board. Otherwise, use change ds1 to set the<br />

Near-End CSU Type field to other.<br />

DS1 circuit pack suffix incorrect for E1 synchronization splitter: The E1 Sync-Splitter<br />

field on the add ds1 screen is set to y but the DS1 circuit pack is not a TN464F or higher<br />

suffix UDS1 board.<br />

If the 402A or 403A E1 synchronization splitter is to be used, remove the circuit pack and<br />

replace it with a TN464F or higher suffix board. Otherwise, use change ds1 to set the E1<br />

Sync-Splitter field to n.<br />

n. Error Type 1310: BLB failure. This error occurs when the DS1 Board Loopback (BLB)<br />

demand test fails. Repeat the test using busyout board location, test ds1-loop<br />

location ds1/csu-loopback-tests, release board location. If the BLB test<br />

continues to fail, replace the TN464F circuit pack.<br />

o. Error Type 1311: ELB failure. This error occurs when the Equipment Loopback (ELB) test<br />

fails for the Integrated CSU (I-CSU) module/T1 sync splitter or for the 402A or 403A E1<br />

synchronization splitter. This test is executed by the I-CSU/E1SS during I-CSU/E1SS<br />

power-up/reset (i.e.- UDS1 board physically inserted and 120A1 CSU module, the 401A T1<br />

sync splitter, or the 402A or 403A E1SS is already installed) or when the 120A1 CSU<br />

module, the 401A T1 sync splitter, or the 402A or 403A E1SS is plugged on to an already<br />

initialized UDS1 DS1 board.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1393