Communication Manager Maintenance Object Repair Procedures<br />

pattern is received unaltered through the loopback. If the transmitted and received patterns are<br />

different, the test fails.<br />

When the test is complete, enter release board to restore all trunks or ports on the DS1<br />

Interface circuit pack to the in-service state.<br />

This test is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 577: DS1 Board Loopback Test (#1209) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry test ds1-loop location ds1/csu-loopback-tests<br />

at 1-minute intervals up to 5 times.<br />

1005 ABORT The DS1 Board Loopback test cannot be executed in the current<br />

configuration. To run this test, the DS1 must be administered for<br />

24-channel operation. The Bit Rate field on the DS1 circuit pack<br />

administration screen must be set to “1.544” for 24-channel operation.<br />

1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out.<br />

1. Enter busyout board location to put all trunks or ports of the<br />

DS1 Interface circuit pack into the out-of-service state.<br />

2. Retry the command.<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system. Executing<br />

this test could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be tested, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

IPSI or Tone-Clock circuit pack using the following command sequence:<br />

1.disable synchronization-switch<br />

2.set synchronization location<br />

3.enable synchronization-switch<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />