Table 271: MEDPRO-C Error Log Entries 2 of 2<br />

Error Type Aux Data Description<br />

10042 (e) Angel Spontaneous interchange to the active state<br />

10051 (f) Angel Spontaneous interchange to the standby state<br />

10052 (f) Angel Spontaneous interchange to the active state<br />

10061 (g) Angel Spontaneous interchange to the standby state<br />

10062 (g) Angel Spontaneous interchange to the active state<br />

10110 (h) Angel The firmware needs to be upgraded<br />

10991 (i) Angel Spontaneous interchange to standby state<br />

10992 (i) Angel Spontaneous interchange to active state<br />

11yy1 (j) Angel Spontaneous interchange to standby state<br />

11yy2 (j) Angel Spontaneous interchange to active state<br />

MEDPRO-C (Media Processor Control)<br />

20001 Angel Craft demand interchange to the standby state<br />

20002 Angel Craft demand interchange to the active state<br />

30000 Angel Active board failure - no interchange to standby. The board will<br />

be taken out of service and calls will be dropped.<br />

40000 Angel Peer link to this board is down. Board problem. To isolate the<br />

problem, see IPMEDPRO (IP Media Processor).<br />

40001 Angel Peer link to this board is up<br />

50000 Angel The inter-board "hellos" have failed. This is a network issue.<br />

50001 Angel The inter-board "hellos" are OK<br />

Notes:<br />

a. Error Type 1: the circuit pack has been removed from the system or is not fully<br />

administered. The error is logged immediately after the circuit pack has been removed or 11<br />

minutes after the SAKI test (#53) fails.<br />

To be fully administered, an IP Media Resource must:<br />

● Have an entry on the circuit pack screen (change circuit-pack)<br />

● Have the Media Resource IP address administered (change node-names)<br />

● Be enabled (change ip-interface)<br />

● Be physically inserted into the correct slot<br />