DID-TRK (Direct Inward Dial Trunk)<br />

3. Refer problem to CO.<br />

c. Error Type 1, Aux Data 57476: Rotary dial before wink occurs when the CO starts dialing<br />

before the PBX sends wink on a wink-start trunk.<br />

1. Verify trunk administered wink/immediate-start parameter.<br />

2. Refer problem to CO.<br />

d. Error Type 1, Aux Data 57477: Rotary dial too early occurs when the CO starts dialing too<br />

soon after seizure on an immediate-start trunk.<br />

1. Verify trunk administered wink/immediate-start parameter.<br />

2. Refer problem to CO.<br />

e. Error Type 1, Aux Data 57483: Rotary dial pulse during wink occurs when the CO sends<br />

rotary dial digits too soon after seizure on a wink-start trunk.<br />

1. Verify trunk administered wink/immediate-start parameter.<br />

2. Refer problem to CO.<br />

f. Error Type 15: software audit error that does not indicate a hardware malfunction. Run<br />

short test sequence, and investigate any associated errors.<br />

g. Error Type 130: the circuit pack or media module has been removed or has been insane for<br />

more than 11 minutes. To clear the error, reinsert or replace the circuit pack or media<br />

module.<br />

h. Error Type 257, Aux Data 57472: Rotary dial pulse on-hook longer than 105 msec, the<br />

break between rotary pulses is too long.<br />

1. Test trunk by performing an incoming test call.<br />

2. Refer problem to CO.<br />

i. Error Type 257, Aux Data 57473: Rotary dial rate below 8 pulses/sec, more than 135 msec<br />

between two successive breaks.<br />

1. Verify trunk administered interdigit-timing parameters.<br />

2. Refer problem to CO.<br />

j. Error Type 257, Aux Data 57474: Rotary dial rate above 12 pulses/sec, less than 75 msec<br />

between two successive breaks.<br />

1. Verify trunk administered interdigit-timing parameters.<br />

2. Refer problem to CO.<br />

k. Error Type 257, Aux Data 57475: Digit detection, CO is starting new rotary dial digit within<br />

150 msec of previous digit.<br />

1. Verify trunk administered interdigit timing parameters.<br />

2. Refer problem to CO.<br />