Note: 2561–2668<br />

VAL-BD (Voice Announcements over LAN Circuit Pack)<br />

l. Error Type 2305-2306: error in received frame from packet bus. Most likely a packet bus<br />

problem.<br />

Error Type 2305 - Received invalid LAPD frame.<br />

Error Type 2306 - Detected parity error on received frame<br />

Invalid LAPD frame errors occur when the frame:<br />

● contains a bad Cyclic Redundancy Check (CRC)<br />

● is greater than the maximum length<br />

● violates the link-level protocol<br />

1. Run test board location and see if the condition clears.<br />

2. If the condition persists, execute the Invalid LAPD Frame Error Counter Test (#597) and<br />

determine whether the condition clears.<br />

3. If the condition persists, execute the Packet Interface Test (#598) to verify circuit pack<br />

integrity.<br />

4. If the Packet Interface test (#598) fails, see PKT-BUS (Packet Bus) for repair procedures.<br />

m. Error Type 2561–2668: system software received an indication that the socket was closed<br />

due to an error. Errors are reported as log only. Errors logged here are for the sockets that<br />

had no processor channels associated with them, for example, sockets to read SNMP data.<br />

The counter base is offset by the application type of the application associated with this<br />

socket that is down. The Aux Data field of the log entry contains this application’s number,<br />

for example, a SNMP application would have its application number in the Aux Data field.<br />

Note:<br />

is a range of reserved numbers for future applications. 2570 currently<br />

represents an SNMP socket failure.<br />

n. Error Type 2817–2819: Congestion Query test (#600) failed.<br />

Error Type 2817 - Every buffer exhausted<br />

Error Type 2819 - Utilized buffers exceed threshold<br />

See Congestion Query Test (#600) for repair procedures.<br />

o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test (#601) failed.<br />

This failure can be due to:<br />

● This circuit pack<br />

● The packet bus<br />

● The packet interface circuit pack.<br />

If: Then:<br />

RSCL disconnects at link level Link fails<br />

Link cannot be reconnected quickly Switch raises MINOR alarm<br />

Communication Manager Release 5.0 Issue 4 January 2008 1403