Communication Manager Maintenance Object Repair Procedures<br />

ADM-CONN (Administered Connection)<br />

MO Name in Log Alarm<br />

Level<br />

ADM-CONN MAJ<br />

MIN<br />

WRN<br />

Initial Command to Run Full Name of MO<br />

status administered-connection n 1 Administered<br />

Connection<br />

1. n is an administered connection number indicated in the PORT field of the Alarm or Error Log.<br />

An administered connection provides an end-to-end connection between two access endpoints<br />

or data modules residing in either the same switch or different switches. When administered,<br />

the connection is automatically established and scheduled to be permanently active.<br />

An error is logged whenever an administered connection fails or cannot be established. A failed<br />

connection generates an error whether or not the connection is subsequently reestablished by<br />

fast retry, re-dial, or auto restoration.<br />

An alarm is logged when an administered connection cannot be established either initially or<br />

after a connection failure. Both the alarm level (none to major) and a failure threshold can be<br />

administered for each administered connection. An alarm is raised when either of the following<br />

occurs:<br />

● The number of consecutive failed attempts to establish a connection reaches the<br />

administered threshold.<br />

● The failure to establish a connection is due to a mistake in administration. See<br />

Table 107: Administered Connection Error Log Entries.<br />

Error log entries and recommended actions<br />

Table 107: Administered Connection Error Log Entries 1 of 2<br />

Error Type Aux Data Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

0, 29 Any None Any OFF None<br />

1, 28 (a, b) Any None Any OFF None<br />

2 (c) Any None Any OFF None<br />

6, 21, 31, 127 (d) Any None Any OFF None<br />

16 (a) Any None Any OFF None<br />

Recommended<br />

action<br />