DS1-BD (DS1 Interface Circuit Pack)<br />

p. Error Type 1313: CPE loopback jack deactivation error. This error occurs when the<br />

TN767E circuit pack could not deactivate a CPE loopback jack loopback.<br />

Attempt to clear the alarm with busyout board location, test ds1-loop location<br />

end-loopback/span-test, and release board location. If the attempt to<br />

deactivate the CPE loopback jack loopback continues to fail, other steps must be taken to<br />

deactivate the loopback.<br />

q. Error Type 1314: Far CSU Loopback deactivation error. This error occurs when the<br />

TN767E circuit pack could not deactivate a far-end CSU loopback on power-up/reset or<br />

upon software request.<br />

Attempt to clear the alarm with busyout board location, test ds1-loop<br />

location end-loopback/span-test, release board location. If the attempt to<br />

deactivate the Far CSU loopback continues to fail, then escalate the problem.<br />

r. Error Type 1538: The hyperactive circuit pack is out-of-service and may exhibit one or<br />

more of the following symptoms:<br />

● The common circuit pack-level tests, such as Test #51 and Test #220, are aborting with<br />

Error Code 2000.<br />

● The tests run on the ports of this circuit pack are returning NO BOARD.<br />

● A busyout/release of the circuit pack has no affect on test results.<br />

● List configuration shows that the circuit pack and ports are properly installed.<br />

The circuit pack is isolated from the system and all trunks of this circuit pack are placed into<br />

the out-of-service state. The system will try to restore the circuit pack within 15 minutes.<br />

When no faults are detected for 15 minutes, the DS1 Interface circuit pack is restored to<br />

normal operation. All trunks of the DS1 Interface circuit pack are then returned to the<br />

in-service state. If the error recurs after 15 minutes, then escalate this problem.<br />

s. Error Type 3160: this board is receiving slips. The AUX Data displays the last Slip count<br />

that was reported.<br />

t. Error Type 3329 - 3345: this board is receiving misframes. The AUX Data displays the last<br />

misframe count that was reported.<br />

u. Error Type 3840: ignore. This error is not service-affecting.<br />

v. Error Type 3900: gives status information about a CPE Loopback Jack test. The value in<br />

the Aux Data field indicates the status of the loopback test:<br />

Aux Data 1: Test is currently running.<br />

Aux Data 2: Test failed because loopback could not be activated.<br />

Aux Data 3: Test failed because test pattern could not be detected.<br />

Aux Data 4: Test has been deactivated.<br />

w. Error Type 3901: gives status information about a Far CSU Loopback test. The value in the<br />

Aux Data field indicates the status of the loopback test.<br />

Aux Data 1: Test is currently running.<br />

Aux Data 2: Test failed because loopback could not be activated.<br />

Communication Manager Release 5.0 Issue 4 January 2008 725