Single-Carrier Cabinet Power Query Test (#79)<br />

Single-Carrier Cabinet Power Query Test (#79)<br />

This test queries an PN’s Maintenance circuit pack about the power status in a single-carrier<br />

cabinet PN. This test can only detect power problems in the carriers of the PN where the Carrier<br />

Port Power Supply physically resides.<br />

This test runs on the DC-POWER (Single-Carrier Cabinet Environment) maintenance object.<br />

Table 412: Single-Carrier Cabinet Power Query Test (#79) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this test are not available.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2. If the test continues to ABORT with a 2000 error code, check for and<br />

resolve every MAINT (Maintenance circuit pack) error. Repeat the<br />

test.<br />

3. If the test still aborts with this error code, escalate the problem.<br />

2029<br />

2319<br />

2320<br />

2500<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />