Communication Manager Maintenance Object Repair Procedures<br />

This test runs on ANN-BD (Announcement circuit pack).<br />

Table 461: Clock Match Inquiry Test (#212) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

2000 ABORT Response to the test request was not received within the time allowed.<br />

1. Enter display errors. If Error Type 1538 is present in the Error<br />

Log for this board, reset the circuit pack.<br />

2. Retry the test at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the test at 1-minute intervals up to 5 times.<br />

ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

FAIL The test failed. Announcements recorded or played back while the clock<br />

circuitry is not functioning properly sound distorted. The ANN-BD may<br />

be defective or the Active Tone-Clock circuit pack (TONE-BD) may be<br />

marginal and is causing this test to fail.<br />

1. Reset the circuit pack with reset board location, then run<br />

this test again.<br />

2. If the test continues to fail, proceed to Step 3 or 4 as applicable.<br />

WARNING: Replacing<br />

WARNING: Replacing<br />

! WARNING:<br />

the circuit pack results in loss of integrated<br />

announcements. See General notes.<br />

3. Replace the ANN-BD. Rerun the test. If the test continues to fail,<br />

replace the Tone-Clock circuit pack.<br />

! WARNING:<br />

the TONE-BD causes a COLD 2 reset. See<br />

Replacing the IPSI or Tone-Clock Circuit Pack. Replacing<br />

the ANN-BD results in loss of integrated announcements.<br />

See General notes.<br />

4. If there are recurring alarms on this circuit pack caused by this test<br />

failing, replace the ANN-BD even if the previous steps were<br />

successful.<br />

1652 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />