Communication Manager Maintenance Object Repair Procedures<br />

Table 579: CSU Repeater Loopback Test (#1211) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system. Executing<br />

this test could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be tested, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

Tone-Clock circuit with the following command sequence:<br />

1.disable synchronization-switch<br />

2.set synchronization location<br />

3.enable synchronization-switch<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

1950 ABORT Another loopback/span test is already executing on the DS1 board or the<br />

board is in a network requested loopback mode (Line loopback or Payload<br />

loopback). The error log indicates whether a Customer Loopback Jack<br />

test, Far CSU Loopback test, or the One-Way Span test is executing or if<br />

the board is in line loopback or payload loopback mode. Only one<br />

long-duration loopback/span test can be active at a given time.<br />

If a loopback/span test is already active, that test must be deactivated via<br />

test ds1-loop location end-loopback/span-test in order to<br />

run this test.<br />

1951 ABORT The CSU Repeater Loopback test could not be executed because the<br />

120A CSU module/T1 sync splitter was not physically installed. Physically<br />

connect the 120A1 CSU module/T1 sync splitter to the TN767E board on<br />

the back of the port carrier.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Check for board hyperactivity. See Hyperactive DS1/UDS1 Interface<br />

Circuit Pack/Media Module.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL DS1 Interface circuit pack failed the CSU Repeater Loopback test.<br />

1. Retry test ds1-loop location ds1/csu-loopback-tests.<br />

2. If the RLB test continues to fail, and the CSU Equipment Loopback<br />

test (#1210) passed, replace the CSU module/T1 sync splitter.<br />