Communication Manager Maintenance Object Repair Procedures<br />

H323-SGR (H.323 Signaling Group)<br />

MO Name in Log Alarm<br />

Level<br />

H323-SGR MIN<br />

WRN<br />

Initial Command to Run Full Name of MO<br />

The H.323 Signaling Group (H323-SGR) MO supports a signaling channel (D-Channel) for<br />

H.323 Trunk connections. The MEDPRO TN802 circuit pack provides audio connectivity,<br />

working in concert with a C-LAN (TN799DP) circuit pack that provides control signaling to<br />

support an H.323 connection.<br />

The H.323 signaling group (H323-SGR) is a Signaling channel that physically resides on a<br />

C-LAN port (socket) and the IP network. Unlike ISDN D-channels, the H.323 channel may<br />

actually come up and down on a call by call basis. The H.323 channel is actually a TCP/IP<br />

signaling channel. Layers 1 and 2 of this signaling channel are monitored by IP PING testing.<br />

Error log entries and recommended actions<br />

Table 231: H323-SGR Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

test signaling-group grp# H323 Signaling Group<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any test signaling-group grp#<br />

1 (b) Any Ethernet Port Status test (#1386) MIN OFF test signaling-group grp#<br />

18 (c) 0 busyout signaling-group<br />

grp #<br />

WRN OFF release signaling-group grp#<br />

257 (d) Any Signaling Group Ping (#1387) MIN OFF test signaling-group grp#<br />

513 (e) Any Signaling Group Ping (#1387) WRN OFF test signaling-group grp#<br />

770 (f) Any WRN OFF<br />

1025 (g) Any MEDPRO Status test (#1392) MIN OFF test signaling-group grp#<br />

1281 (h) Any MEDPRO Status test (#1392) MIN OFF<br />

1537 (i) Any<br />

1794 (j) MEDPRO Status test (#1392) MIN OFF test signaling-group grp#<br />

2049 (k) Keep Alive Failure MIN OFF<br />

2305 (l) Gateway Unregistered Inline Error MIN OFF<br />