Communication Manager Maintenance Object Repair Procedures<br />

Table 512: Electronic Power Feed Inquiry Test (#622) 2 of 2<br />

Error<br />

Code<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. If the test aborts repeatedly up to five times, reset the circuit pack<br />

and rerun the test.<br />

2. If the test aborts again, replace the circuit pack.<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

CRC Error Counter Test (#623)<br />

Internal system error.<br />

Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2. If the test continues to abort, escalate the problem.<br />

1 FAIL The BRI-LINE circuit pack reports that it has detected an overcurrent<br />

condition and has turned off the EPF.<br />

1. As necessary, check and repair the wiring between the circuit pack<br />

and the endpoint or adjunct. Check the endpoints and replace one or<br />

both sets if the sets are drawing too much current. Enter test port<br />

location and review the results of the EPF Inquiry test to verify the<br />

repair. If this test is still failing, proceed to step 2.<br />

2. Enter test port location, and review the results of the Level 1<br />

Status Inquiry test. If this test is also failing, then follow the repair<br />

procedure for the Level 1 Status Inquiry test. Otherwise, escalate this<br />

problem to the next tier.<br />

PASS The Electronic Power Feed Inquiry test reports that the EPF is on.<br />

This test reads the port’s CRC error counters that are maintained on the circuit pack. The Cyclic<br />

Redundancy Check (CRC) is a means of error detection to determine the integrity of data frame<br />

contents. The CRC error counter is incremented by the circuit pack when it detects a CRC error.<br />

The test passes if the value of the counter is 0, meaning the error is cleared. If the counter is<br />

non-zero, the test fails and the value of the counter is displayed in the Error Code field.<br />

This test runs on ASAI-PT (ASAI Port), BRI-PORT (ISDN-BRI Port), and TBRI-PT (ISDN<br />

Trunk-Side BRI Port).<br />

1760 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />