Table 99: Media Gateway Traps and Resolutions 7 of 22<br />

Event<br />

ID<br />

Trap # Alarm<br />

Level<br />

Description / Recommendation<br />

G700 Traps<br />

11 24 MAJ cmg8260PowerFault — The voltage reading at the +2.5V power<br />

source serving the 8260 processor is out of tolerance.<br />

1. Replace the power supply only if the problem is persistent.<br />

Do not replace the power supply if there is a suspected<br />

voltage spike or temporary brown-out.<br />

11 25 MAJ cmg8260PowerClear - The voltage reading at the +2.5V power<br />

source serving the 8260 processor is back within its tolerance<br />

range.<br />

12 26 MAJ cmgAuxPowerFault - The voltage reading at the -48V auxiliary<br />

power source serving the end points is out of tolerance.<br />

1. No action is required.<br />

12 27 MAJ cmgAuxPowerClear - The voltage reading at the -48V auxiliary<br />

power source serving the end points is back within its tolerance<br />

range<br />

13 28 MAJ cmgFanPowerFault - The voltage reading at the +12V auxiliary<br />

power source serving the fans is out of tolerance.<br />

1. Replace the power supply only if the problem is persistent.<br />

Do not replace the power supply if there is a suspected<br />

voltage spike or temporary brown-out.<br />

13 29 MAJ cmgFanPowerClear - The voltage reading at the +12V auxiliary<br />

power source serving the fans has returned to within its tolerance<br />

range.<br />

7 of 22<br />

Communication Manager Release 5.0 Issue 4 January 2008 395