Table 498: Expansion Interface Packet Interface Test (#589) 2 of 5<br />

Error<br />

Code<br />

1033<br />

(cont’d)<br />

Test<br />

Result<br />

ABORT<br />

(cont’d)<br />

Description / Recommendation<br />

Expansion Interface Packet Interface Test (#589)<br />

Center Stage:<br />

If the EI circuit pack under test resides in the PN:<br />

None of the EI circuit packs located in the PNs (on the same PNC side)<br />

are in service (for PN EIs see the next case).<br />

5. Enter list fiber-linklist fiber-link to determine whether<br />

any of the PN’s EI circuit packs are administered as endpoints of a<br />

fiber link. If not, then ignore the results of this test.<br />

6. Enter list conf for the cabinets and carriers where the EI circuit<br />

packs reside in every other PN. If the results returned indicated that<br />

the circuit packs are not recognized by software, they are out of<br />

service for this reason.<br />

7. Enter display errors, and resolve any EXP-PN (Expansion Port<br />

Network)errors. Re-run this test.<br />

8. If the test continues to abort with this error code, reseat the EI circuit<br />

packs (or DS1 converter circuit pack if so equipped) on the PNs. This<br />

will not be destructive since the circuit pack cannot be serving as the<br />

Expansion Archangel if it is not in service.<br />

9. Run Test #237 on each of the PN EI circuit packs, and check for<br />

EXP-INTF circuit pack Error Type 1281 in the error log. If Error Type<br />

is present and/or Test #237 does not pass, see repair procedures for<br />

Expansion Interface Neighbor Query Test (#237).<br />

10. Repeat this test.<br />

If the EI circuit pack under test resides in the PN:<br />

The EI circuit located in the PN is out of service.<br />

1. Run Test #237 on each of the PN EI circuit packs and check for<br />

EXP-INTF circuit pack Error Type 1281 in the error log. If Error Type<br />

is present and/or Test #237 does not pass, see repair procedures for<br />

Expansion Interface Neighbor Query Test (#237).<br />

2. Repeat this test.<br />

2 of 5<br />