TONE-PT (Tone Generator)<br />

TONE-PT (Tone Generator)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

TONE-PT MAJ<br />

MIN<br />

Note:<br />

Note: Replacing the IPSI or Tone-Clock circuit pack requires a special procedure which<br />

is described in TONE-BD (Tone-Clock Circuit Pack). That section also describes<br />

the LED display for this board.<br />

The tone generator resides on the IPSI or Tone-Clock circuit pack and provides all system tones<br />

such as dial tone, busy tone, and so on. If an active tone generator fails, its port network may<br />

not have tones (see Tone Generator Transmission Test (#40). For instance, a user may go<br />

off-hook and hear no dial tone. This problem will affect only users on the same port network<br />

where the faulty IPSI or Tone-Clock circuit pack resides. The system will be able to process<br />

certain type of calls (that is, internal calls will succeed while outgoing calls will not).<br />

The IPSI or Tone-Clock circuit pack also provides the clocks for the system and can serve as<br />

the synchronization reference. Therefore, when resolving alarms, use the TDM-CLK (TDM Bus<br />

Clock), SYNC (Port Network Synchronization), and TONE-BD (Tone-Clock Circuit Pack) repair<br />

procedures.<br />

See TONE-BD (Tone-Clock Circuit Pack) for a discussion of the relationship of Tone-Clock<br />

circuit packs with the various reliability options.<br />

Error log entries and recommended actions<br />

test tone-clock location Tone Generator<br />

WRN release tone-clock location<br />

Table 365: TONE-PT Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended<br />

Action<br />

0 (a) 0 Any Any Any test tone-clock<br />

location 1<br />

1 (b) 17664 Tone Generator Audit/<br />

Update (#41)<br />

MAJ<br />

MIN 2<br />

ON test tone-clock<br />

location r 2<br />

18 (c) 0 busyout tone-clock location WRN OFF release<br />

tone-clock<br />

location<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1369