Communication Manager Maintenance Object Repair Procedures<br />

The test passes only if both the signaling link is connected and the test frame is successfully<br />

transmitted.<br />

A failure may indicate a problem with:<br />

● this circuit pack<br />

● the packet bus<br />

● the Packet Interface circuit pack<br />

Table 505: Link Status Test (#601) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1125 ABORT RSCL link or circuit pack not in service.<br />

1. Release the circuit pack with release board location.<br />

2. Repeat the test.<br />

3. Escalate if the problem persists.<br />

2012 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2100 ABORT Internal system error.<br />

1. Retry command at 1-minute intervals up to 5 times.<br />

2. If the problem persists, escalate the problem.<br />

2 FAIL The RSCL control link is disconnected.<br />

1. Retry command at 1-minute intervals up to 5 times.<br />

2. If the test continues to fail, run the Packet Interface test (#598) with<br />

test board location to determine if the problem is due to the<br />

circuit pack.<br />

3. If the Packet Interface test (#598) fails, see Packet Interface Test<br />

(#598) for repair procedures.<br />

4. If the Packet Interface test (#598) passes, refer to PKT-BUS<br />

(Packet Bus) repair procedures.<br />

3 FAIL Received no response to RSCL control link test frame.<br />

1. Retry command at 1-minute intervals up to 5 times.<br />

2. If the problem persists, reset the circuit pack with<br />

reset board location.<br />

3. If test continues to fail, replace the circuit pack.<br />