Table 590: ATM Board Reset (#1256) 2 of 2<br />

Error<br />

Code<br />

ATM Board Reset (#1256)<br />

1407 ABORT This test cannot be run on an ATM-EI board that is on the active PNC<br />

because it cannot be busied out. This error code indicates that PNC<br />

duplication is enabled.<br />

1. Attempt to perform a PNC interchange with<br />

reset pnc interchange<br />

2. If the PNC interchange is successful, busyout the original<br />

ATM-Expansion Interface circuit pack with busyout board<br />

location (address of the original ATM-EI board)<br />

3. Retry the command.<br />

2000 ABORT Did not receive the response in the allowed time.<br />

1. Verify that the board is seen by the system with list config all.<br />

2. If the board is visible, run the test again. If the same abort code recurs,<br />

escalate the problem.<br />

3. If the board is not visible to the system with list config all,<br />

reseat the board.<br />

4. If the board is still not recognized by the system, replace the board.<br />

2100<br />

2500<br />

1<br />

2<br />

Test<br />

Result<br />

ABORT Could not allocate the necessary system resources to run this test.<br />

Internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL The circuit pack failed to reset.<br />

The circuit pack failed to restart.<br />

1. Run the command again.<br />

2. If the problem persists, replace the circuit pack.<br />

PASS The ATM circuit pack was successfully reset.<br />

ATM-EI:<br />

1. If status port-network still indicates that this link is down, it is<br />

possible that one or both of the ATM-EI circuit packs are busied out.<br />

Review the error logs and take appropriate diagnostic action for<br />

ATM-EI (Expansion Interface Circuit Pack)<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

2 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1955