Table 453: Digital Looparound Test (#171) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Digital Looparound Test (#171)<br />

1180 ABORT There is no Maintenance/Test circuit pack digital port available for testing.<br />

1. Check if the Maintenance/Test digital ports are present. Enter<br />

list config. Ports 02 and 03 should be displayed.<br />

2. If the digital ports 02 and 03 on the Maintenance/ Test circuit pack are<br />

not present, see M/T-BD (Maintenance/Test Circuit Pack).<br />

3. If the digital ports are present, retry the command at 1-minute<br />

intervals up to 5 times.<br />

1181 ABORT No time-slots available to connect digital ports for the test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1182 ABORT Internal system error. Failed to connect the digital ports with time-slots.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1340 ABORT No Maintenance/Test digital port is currently available to perform this test.<br />

1. Enter list config to determine whether the Maintenance/Test<br />

digital ports (ports 02 and 03 on the Maintenance/Test circuit pack)<br />

are present in the system. At least one Maintenance/Test circuit pack<br />

must be present in PN 1 of the system. There should be at least two<br />

such ports present. If the ports are present, proceed to step 2.<br />

Otherwise, determine why no ports appear in the list config<br />

display. Refer to M/T-DIG (Maintenance/Test Digital Port) and M/T-BD<br />

(Maintenance/Test Circuit Pack).<br />

2. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

3. If the ports are present and no errors are logged against them, retry<br />

the command at 1-minute intervals up to 5 times.<br />

4. If the test continues to abort, replace the Maintenance/Test circuit<br />

pack.<br />

1392 ABORT This port is a TTI port. The test does not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port (the<br />

display shows that the port is a TTI port) or list config (a “t” is<br />

displayed for the port).<br />

2. If either list config or display port indicates that the port is<br />

not a TTI port, escalate the problem. If both commands indicate that<br />

the port is a TTI port, no action is necessary.<br />

2 of 4<br />

Communication Manager Release 5.0 Issue 4 January 2008 1633