Table 182: DIG-LINE Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

DIG-LINE (Digital Line)<br />

130 (e) WRN ON test port location<br />

257 (f) 40971<br />

513 0 Digital Station<br />

Audits (#17)<br />

WRN OFF test port location r 6<br />

767 (g) 40964 WRN OFF<br />

769 (h)<br />

(i)<br />

40963<br />

40988<br />

WRN OFF<br />

1026 (j) WRN OFF<br />

1281 Any Digital Station<br />

Audits (#17)<br />

WRN OFF test port location r 4<br />

1537 (k) 40968 WRN OFF<br />

1793 Voice and Ctrl.<br />

Local Loop test<br />

(#13)<br />

2049 GPP NPE<br />

Crosstalk Test<br />

(#9)<br />

2304 (l)<br />

2305 (m)<br />

(n)<br />

32770<br />

40969<br />

2817 (o) Any OFF<br />

3585 (p)<br />

3840 (q)<br />

(r)<br />

40965<br />

40989<br />

3841 (s) 41029<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

MIN ON test port location l r 3<br />

1<br />

WRN<br />

MIN ON test port location l r 3<br />

2<br />

WRN<br />

1. Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence.<br />

b. Error Type 1, Aux Data 40987 could indicate a noisy port or link. This is an off-board<br />

problem detected by the port circuit. Check for defective wiring, a defective voice terminal,<br />

Communication Manager Release 5.0 Issue 4 January 2008 699