Communication Manager Maintenance Object Repair Procedures<br />

Table 532: SNI Destructive Facility On-board Test (#757) 2 of 3<br />

Error<br />

Code<br />

2100<br />

2300<br />

2301<br />

2304<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this test.<br />

The downlink message necessary to run this test could not be sent.<br />

The timer could not be set before sending the downlink message.<br />

SNI circuit pack is not able to run the test requested by software.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2306 ABORT The SNI circuit pack is not responding to test requests sent by software.<br />

1. Run test led switch-node for the switch node where the SNI<br />

board(s) reside to verify whether their LEDs light.<br />

2. If LEDs light on the other boards in the same carrier but not on this<br />

board, enter test board location long to run Test #760 for<br />

the active SNC in this carrier. Wait 5 minutes, and try step 1 again. If<br />

the board’s LEDs still do not light, replace the board. Replacing an<br />

SNI may be service interrupting. Refer to SNI-BD (SNI Circuit Pack)<br />

for the procedure to replace an SNI.<br />

3. If none of the LEDs light for the boards in the same carrier as this<br />

board, fix any problems associated with the connectivity of this<br />

carrier to the server.<br />

a. Check list fiber-link to see the fiber connections to this<br />

carrier.<br />

b. Check the LEDs on every SNI and EI, and fix any fiber problems.<br />

c. Enter display errors, and follow the repair procedures for<br />

any EXP-INTF error entries associated with the controlling IPSI<br />

connected PN.<br />

d. Follow the repair procedures if there are errors for any of the<br />

following:<br />

● SYNC (Port Network Synchronization)<br />

● SNI-BD (SNI Circuit Pack)<br />

● SNC-BD (Switch Node Clock Circuit Pack)<br />

● FIBER-LK (Fiber Link)<br />

● SNI-PEER (SNI Peer Link)<br />

e. For SNI-BD, see Switch Node Interface Manual Loopback<br />

Procedure to determine whether the circuit pack or the fiber<br />

connection is faulty.<br />

1806 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />