09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CONFIG (System Configuration)<br />

Table 174: Converting Error Types To Carrier Locations 5 of 5<br />

Error Type Carrier Location<br />

103 C06<br />

104 C07<br />

105 C08<br />

106 C09<br />

107 C10<br />

108 C11<br />

109 C12<br />

110 C13<br />

111 C14<br />

112 C15<br />

113 C16<br />

114 C17<br />

115 C18<br />

116 C19<br />

117 C20<br />

118 C00 (d)<br />

119 (a)<br />

5 of 5<br />

Notes:<br />

a. Error Types 1, 23, 25, 25, 26, 32, 33, 55, 64, 65, 87, 96, 97, 119 do not represent physical<br />

port circuit pack slots and are not logged against CONFIG.<br />

b. If Error Type 28 occurs in a PN, it refers to the circuit pack in slot A01.<br />

c. If Error Type 61 occurs in a PN, it refers to the circuit pack in slot A10.<br />

d. Error Type 22, 54, 86, 118: Slots B00, C00, D00, and E00 refer to the Service Slots in the<br />

B, C, D, and E carriers.<br />

e. Error Type 27: In a PN’s A carrier, slot A00 is the Tone Generator’s slot.<br />

Communication Manager Release 5.0 Issue 4 January 2008 669