Communication Manager Maintenance Object Repair Procedures<br />

Table 641: Power Supply Temperature Test (#1537) 2 of 2<br />

Error<br />

Code<br />

1<br />

2<br />

3<br />

Test<br />

Result<br />

FAIL The inlet temperature is over threshold.<br />

The exhaust temperature is over threshold.<br />

Both the inlet and the exhaust temperatures are over threshold.<br />

1. Enter test board location to check the temperature.<br />

2. If redundant power supplies are present, there may be a problem<br />

with the backplane. Verify that each power supply can detect the<br />

problem by using recycle carrier, specifying the slot number of<br />

the power supply to be shut down. Refer to the notes and cautions<br />

for this command in Maintenance Commands Reference<br />

(03-300431) before executing recycle carrier.<br />

3. Replace the power supply.<br />

4. If the problem persists, check the backplane for shorts.<br />

4 FAIL There is a hot spot temperature warning.<br />

8 FAIL There is a hot spot temperature shutdown.<br />

0 NO<br />

BOARD<br />

Description and recommendation<br />

PASS The inlet, exhaust, and hot spot temperatures are within limits.<br />

The power supply is administered but not detected.<br />

1. Verify that the power supply is plugged in.<br />

2. Replace the power supply.<br />