TDM-CLK (TDM Bus Clock)<br />

c. If not, replace the standby Tone-Clock circuit. See Replacing the IPSI or Tone-Clock<br />

Circuit Pack.<br />

If this clears the error, the problem has been resolved.<br />

5. Replace the EI circuit pack for the active PNC.<br />

6. If the problem is still not cleared and the IPSI or Tone-Clock circuit pack reported in the<br />

error log has not yet been replaced, replace it. See Replacing the IPSI or Tone-Clock<br />

Circuit Pack.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

Reset<br />

Board<br />

Sequence<br />

SAKI Sanity Test (#53) X D<br />

Clock Health Inquiry Test (#46) X X ND<br />

Control Channel Looparound Test (#52) X X ND<br />

Tone Generator Crosstalk Test (#90) X ND<br />

Tone Generator Transmission Test (#40) X X ND<br />

Tone Generator Update/Audit Test (#41) X X ND<br />

TDM Bus Clock Circuit Status Inquiry Test (#148) X X ND<br />

TDM Bus Clock Slip Inquiry Test (#149) X X ND<br />

TDM Bus Clock PPM Inquiry Test (#150) X X ND<br />

TDM Bus Clock Parameter Update Test (#151) X X ND<br />

Board Type Check Test (#574) X X ND<br />

Standby Reference Health Check Test (#651) X ND<br />

1. D = Destructive; ND = Nondestructive<br />

D/ND 1<br />