09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

● XXX-BD (Common Port Circuit Pack/Media Module).<br />

Table 398: Ringing Application Test (#51) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error. Could not allocate the necessary system resources<br />

to run test. The circuit pack is not installed.<br />

1000 ABORT System resources required to run test are not available.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the test.d.<br />

1. Enter display port location to determine the station extension.<br />

Enter status station to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port is<br />

idle before retesting.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the<br />

ringing circuits are in use; the ringing generator is defective; ringing<br />

generator is not wired correctly.<br />

1. If the test continues to abort, look for RING-GEN errors in the Error<br />

Log.<br />

a. If there are RING-GEN errors, see RING-GEN (Analog Ring<br />

Generator) and try to resolve any problem(s). Then retry the test at<br />

1-minute intervals up to 5 times.<br />

b. If there are no RING-GEN errors, and the test continues to abort,<br />

enter test board location on other TN742, TN769, or TN746<br />

Analog circuit packs. If an ABORT with Error Code 1008 occurs for<br />

this test on other circuit packs as well, then the ringing generator<br />

may be defective or may not be wired properly. See RING-GEN<br />

(Analog Ring Generator) maintenance documentation for details. If<br />

an ABORT with Error Code 1008 does NOT occur on the other<br />

ports, then all four ring generators are in use. No further action is<br />

necessary.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

1412 ABORT This test does not run on media modules or media gateways. Ignore.<br />

1514 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!