Communication Manager Maintenance Object Repair Procedures<br />

Table 323: S-SYN-PT Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

257 Speech Synthesis PSS Handshake<br />

test (#168)<br />

513 17922 Speech Synthesis Memory test<br />

(#166)<br />

769 17664 Speech Synthesis DTMF Sanity<br />

Inquiry (#164)<br />

1025 17670 Speech Synthesis SSD Inquiry test<br />

(#167)<br />

1281 Speech Synthesis DSP Tone test<br />

(#165)<br />

1537 Speech Synthesis Memory test<br />

(#166)<br />

1793 Speech Synthesis DTMF Receiver<br />

test (#163)<br />

MAJ ON test port location r 2<br />

MIN ON test port location r 2<br />

MIN ON test port location r 2<br />

MIN ON test port location r 2<br />

MIN ON test port location r 2<br />

MIN ON test port location r 2<br />

MIN ON test port location l r 2<br />

2049 (d) Conference Circuit Test (#7) MIN ON test port location l r 2<br />

2305 NPE Crosstalk Test (#6) MIN ON test port location l r 2<br />

3840 (e) Any<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />

b. Error Type 1: an inline failure of the on-board microprocessor/PSS handshake has<br />

occurred. Refer to Speech Synthesis PSS Handshake Test (#168) for repair procedures.<br />

c. Error Type 130: the circuit pack been removed or has been insane for more than 11<br />

minutes. To clear the error, reinsert or replace the circuit pack.<br />

d. Error Type 2049: a transient error that does not cause an alarm can occasionally occur<br />

during a server, TDM bus, or Tone-Clock interchange. Test the port, and follow the repair<br />

procedures for the Conference Circuit Test (#7).<br />

e. Error Type 3840: this error is not service-affecting, and no action is required.<br />