Table 558: Packet Interface Reset Test (#889) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Packet Interface Reset Test (#889)<br />

1335 ABORT Internal IPSI error. The Packet Interface module is on the standby IPSI,<br />

and this test is not allowed to run.<br />

1. Enter set ipserver-interface Uc to make the standby Packet<br />

Interface active.<br />

2. Run the test.<br />

1362 ABORT The Reset test is not allowed to run because the Packet Interface is in<br />

service. Resetting an active IPSI circuit pack’s Packet Interface module<br />

while in service is not allowed because this is a destructive test.<br />

1. Enter status packet-interface to determine the service state<br />

of the Packet Interface. If the Packet Interface is out of service, try<br />

the Reset command again.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

5001 ABORT The TDM clock in the Processor port network has failed.<br />

1. See TDM-CLK (TDM Bus Clock) to clear this failure.<br />

5002 ABORT The packet bus in the Processor port network has failed.<br />

1. See PKT-BUS (Packet Bus) to clear this failure.<br />

Any FAIL The diagnostic tests failed for the IPSI’s Packet Interface module. If the<br />

system is equipped with the high-reliability or critical-reliability<br />

configuration, the reset runs only on demand if the Packet Interface is<br />

on the standby IPSI circuit pack or if Packet Interface is in an<br />

out-of-service state on the active IPSI.<br />

1. This may be the result of old firmware not supporting new software<br />

operation. Verify the IPSI circuit pack’s firmware vintage and<br />

download the new firmware if appropriate.<br />

2. The firmware image on the IPSI circuit pack may have been<br />

corrupted. Download the firmware image.<br />

3. Retry the command.<br />

4. If the same Error Code occurs, retry reset packet-interface.<br />

5. If the reset fails, replace the IPSI circuit pack.<br />