VC-DSPPT (Voice Conditioner DSP Port)<br />

VC-DSPPT (Voice Conditioner DSP Port)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

VC-DSPPT MAJ<br />

MIN<br />

WRN<br />

Each Voice Conditioner circuit pack (VC-BD) provides two types of resources:<br />

● Transcoder Resources used for encoding and decoding audio formats<br />

● Summer Resources used for summing audio from different sources<br />

The eight Voice Conditioner DSP ports are the transcoder resources on the VC-BD.<br />

Error log entries and recommended actions<br />

Table 371: VC-DSPPT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

test port location Voice Conditioner DSP Port<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test port location<br />

18 (b) 0 busyout port<br />

location<br />

257 (c) Any VC DSP NPE Crosstalk<br />

Test (#1103)<br />

513 (d) Any VC DSP Port Local TDM<br />

Loopback test (#1104)<br />

778-781<br />

(e)<br />

Any VC Port Reset DSP test<br />

(#1106)<br />

WRN OFF release port location<br />

MIN ON test port location 1 r 3<br />

MIN ON test port location r 3<br />

MAJ ON<br />

1025 (f) WRN ON<br />

1281 (g) Any VC DSP Port DSP<br />

Loopback test (#1105)<br />

3840 (h)<br />

MIN ON test port location r 3<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each appropriate test’s description, and follow its recommended<br />

procedures.<br />