Communication Manager Maintenance Object Repair Procedures<br />

Table 377: Dial Tone Test (#0) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

2002 FAIL Seizure portion of the test failed due to a hardware problem. The fault is<br />

usually caused by a disconnected trunk.<br />

CO-TRK:<br />

1. If the CO Port Diagnostic Test (#3) also failed, enter display<br />

errors to display the error log. If Error Type 1281 appears in the<br />

error log (the CO Port Diagnostic Test failed because it could not<br />

detect ground) AND Error Type 3329 or 3585 appears in the error<br />

log with the same last occurred time as Error Type 1281 and 1537,<br />

replace the circuit pack or media module.<br />

2. Check the trunk wiring to ensure good connection. Repeat the test if<br />

a wiring correction is made.<br />

3. Locate another identical CO trunk and swap its wiring with the one<br />

under test. Repeat the test on both trunks, and determine whether<br />

the problem follows the trunk or remains at the original port. If the<br />

problem follows the trunk, refer the problem to the CO. If the<br />

problem remains at the port, replace the circuit pack or media<br />

module and repeat the test.<br />

DIOD-TRK:<br />

1. Check trunk wiring to ensure good connection. Repeat the test if a<br />

wiring correction is made.<br />

2. Locate another identical CO trunk and swap its wiring with the one<br />

under test. Repeat the test on both trunks and determine whether<br />

the problem follows the trunk or remains at the original port. If the<br />

problem follows the trunk, refer the problem to the CO. If the<br />

problem remains at the port, replace the circuit pack and repeat the<br />

test.<br />

Any NO<br />

BOARD<br />

Description / Recommendation<br />

PASS Trunk was seized, and dial tone was detected. Investigate user-reported<br />

troubles on this port by using other port tests and by examining the trunk<br />

or external wiring.<br />

See NO BOARD for the repair procedures.<br />