i. Error Type 1793: operational failure.<br />

1. Run test board location.<br />

Aux Data Description<br />

1 No AC or DC input<br />

2 The power supply is off because of a system command.<br />

4 Failure, voltage, temperature, or internal status fault<br />

POW-SUP (Power Supply)<br />

j. Error Type 2049: input power failure. A warning alarm is generated when the problem is<br />

first detected. The alarm level will change to a Minor alarm after about 50 minutes if the<br />

problem does not clear.<br />

1. Run test board location.<br />

2. Run status environment.<br />

k. Error Type 2305: aux sig lead failure.<br />

1. Run test board location.<br />

2. Run status environment.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

Reset Test<br />

Sequence<br />

Power Supply Recycle Test (#1534) X D<br />

Power Supply Detection Test (#1535) X X ND<br />

Power Supply Voltage Test (#1536) X X ND<br />

Power Supply Aux Signal Test (#1649) X X ND<br />

D/ND<br />