Table 384: Local Loop Test (#13) 7 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Local Loop Test (#13)<br />

14 FAIL The primary information channel is not transmitting properly.<br />

1. Check the Tone Generator and the Tone Detector circuit packs by<br />

entering test board location for these circuit packs.<br />

2. Resolve any problems detected on the Tone Generator or Tone<br />

Detector circuit pack and retest.<br />

3. If the Tone Generator and Tone Detector circuit packs are<br />

functioning properly and the test still fails,<br />

ADX8D-PT and ADX16D-P: Shut down AUDIX and replace the<br />

EMBEDDED AUDIX circuit pack.<br />

DIG-LINE, E-DIG-ST, PDMODULE, and TDMODULE: Replace<br />

the Digital Line circuit pack.<br />

M/T-ANL and M/T-DIG: Replace the Maintenance/Test circuit<br />

pack.<br />

7 of 9<br />

Communication Manager Release 5.0 Issue 4 January 2008 1471