Communication Manager Maintenance Object Repair Procedures<br />

Table 184: DIOD-TRK Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

1537 Dial Tone Test (#0) MAJ<br />

MIN<br />

WRN 1<br />

1793 Looparound and Conference<br />

Test (#33)<br />

MAJ<br />

MIN<br />

WRN 1<br />

2049 NPE Crosstalk test (#6) MAJ<br />

MIN<br />

WRN 1<br />

2561 (d) 57345<br />

2817 (e) 57393<br />

3073 (f) 57376<br />

3585 (g) 57424<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

ON test port long r 2<br />

ON test port long r 3<br />

ON test port long r 3<br />

1. Major alarms on this MO may be downgraded to Warning alarms based on the value in set options. If<br />

the Minor alarm is not downgraded by set options values, the Minor alarm is upgraded to a Major alarm<br />

if 75 percent of the trunks in this trunk group are alarmed.<br />

Additional Information:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its recommended procedures.<br />

b. Error Type 15: software audit error and does not indicate any hardware malfunction. Run<br />

the short test sequence, and investigate associated errors.<br />

c. Error Type 769, Aux Data 57392 are inline errors that have no specific test associated with<br />

them. The CO is not releasing after the call is dropped from the PBX end. After several<br />

occurrences, an off-board warning alarm is generated. Refer the problem to the CO.<br />

d. Error Type 2561, Aux Data 57345: Single polarity ringing current. This is an inline error<br />

that has no specific test associated with it. This error results from abnormal ringing current,<br />

but does not prevent the incoming call from being accepted. This error code is logged for<br />

information purposes only and does not cause additional testing to occur. One cause could<br />

be that the reverse current detector associated with the port is failing. (Will not be detected<br />

by any tests.) The other cause could be that normal current is not detected. In this case,<br />

neither incoming nor outgoing calls can be completed, and the Dial Tone test (#0) also fails.<br />

Check for other errors.<br />

712 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />