09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

140AY Looparound Test (#210)<br />

This test checks the integrity of the record channel on the Announcement circuit pack<br />

(Announcement Port 1).<br />

Since this test involves sending a tone through two different ports, the Playback Speech<br />

Memory Array Test (#206) is run on the two ports first to make sure that they are working<br />

properly.<br />

This test runs on ANN-BD (Announcement circuit pack).<br />

Table 459: 140AY Looparound Test (#210) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

1-3 ABORT Response to the test was not received within the time allowed. The error<br />

code indicates at which speech compression rate the test aborted (one<br />

being the first rate tested, three being the last).<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

10 ABORT The PSMA Test (#206) failed on Announcement Port 1.<br />

90 The PSMA Test (#206) failed on Announcement Port 9.<br />

1. Refer to Playback Speech Memory Array Test (#206).<br />

1000 ABORT System resources required to run this test are not available. This test<br />

needs Announcement Ports 1 and 9 to run. One of the ports may be in use<br />

on a valid call.<br />

1. Retry the command at 1-minute intervals a maximum of 5 times.<br />

2. If the test continues to abort and Ports 1 and 9 are not in use, escalate<br />

the problem.<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS errors. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1648 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!