Communication Manager Maintenance Object Repair Procedures<br />

j. Error Type 1793: this error can be caused by one of the following conditions:<br />

● One or both TOCs (Timing Output Cards) has failed.<br />

● The connection between the Stratum-3 clock and the TN780 Tone-Clock circuit pack is<br />

faulty.<br />

● The TN780 Tone-Clock circuit pack is defective.<br />

Demand test descriptions and error codes<br />

The test synchronization command also runs the Synchronization Update Test (#417).<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND<br />

Stratum-3 Clock Alarm Query (#649) X X Non-Destructive<br />