09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

Clearing Firmware Errors<br />

DS1 converter error reports are generated by firmware autonomously. DS1 converter error<br />

reports are not associated with demand tests. The test board clear command does not<br />

affect the error status known by the DS1 converter firmware. To clear every on-board<br />

firmware-detected error unconditionally, use clear firmware-counters.<br />

Error log entries and recommended actions<br />

Table 190: DS1-FAC Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any test ds1-facility location<br />

1 (b) Failure Audit #949 MAJ ON test board location<br />

18 (c) 0 busyout<br />

ds1-facility<br />

location<br />

WRN OFF release ds1-facility location<br />

257 (d) Failure Audit #949 MIN ON test board location<br />

513 (e) 1 Failure Audit #949 MIN OFF test board location<br />

513 (e) 2 Failure Audit #949 MIN OFF test board location<br />

856 (f) DS1 Facility Query for<br />

Slips/Misframes #972<br />

1025 (g) Failure Audit #949 MAJ 1<br />

1281 (h) None Failure Audit #949 MAJ 1<br />

1281 (h) 1 Failure Audit #949 MAJ 1<br />

1281 (h) 2 Failure Audit #949 MAJ 1<br />

1537 (i) Failure Audit #949 MAJ 1<br />

MIN OFF none<br />

OFF test board location<br />

OFF test board location<br />

OFF test board location<br />

OFF test board location<br />

OFF test board location<br />

1793 (j) Failure Audit #949 MAJ 1 OFF test board location<br />

2065 (k) DS1 Facility Query for<br />

Slips/Misframes #972<br />

MIN OFF none<br />

2305 (l) Failure Audit #949 MAJ OFF test board location<br />

2561 (m) Failure Audit #949 MIN 1 OFF test board location<br />

1. These failures are logged as a WRN alarm when the error is first reported. The alarm severity is raised to a<br />

MAJOR in 15 minutes if the problem persists.<br />