Communication Manager Maintenance Object Repair Procedures<br />

In a CSS configuration with duplicated Port Network Connectivity (PNC), EI circuit packs reside<br />

in the Switch Node Carrier (see Figure 63: Center Stage Switch Configuration with Duplicated<br />

PNC). In this case, the EI and SNI circuit packs may be connected via a metallic cable instead<br />

of an optical fiber link. Metallic cable should be tested and replaced in the same manner as<br />

optical fiber.<br />

A PN-to-PN connection can be extended through a DS1 converter complex. (See<br />

Figure 64: Fiber Link with DS1 Converter Complex). When discussing problems that may be<br />

related to fiber links, the DS1 converter is considered part of the fiber link. If diagnosis of the<br />

problem points to fiber connectivity and a DS1 converter circuit pack is part of the connectivity,<br />

problems with the DS1 converter circuit pack should be investigated (see DS1C-BD (DS1<br />

Converter Circuit Pack)). The DS1 converter circuit pack runs diagnostics for the EI circuit pack<br />

via such tests as the Expansion Interface Neighbor Query Test (#237), the Expansion Interface<br />

Fiber Out-of-Frame Query Test (#238), the Expansion Interface 2-Way Transmission Test<br />

(#241), and the Expansion Interface Packet Interface Test (#589).<br />

In a critical-reliability system, the fiber link’s are duplicated as part of PNC duplication. In a<br />

high-reliability system with a CSS (Center Stage Switch) and unduplicated PNC, a single point<br />

of failure between the server and the CSS is eliminated by duplicating each link, consisting of:<br />

● SNI in the CSS to which the PN’s EI connects<br />

● Physical fiber paths between them<br />

These dual connections normally share the call-processing load. Should one of these links fail,<br />

the entire load can be shifted to the operational link.<br />

Figure 60: Direct Connect Configuration with Unduplicated PNC shows the location of the EI<br />

circuit packs in a typical unduplicated PNC, direct connect configuration.<br />

Figure 60: Direct Connect Configuration with Unduplicated PNC<br />

Slot #<br />

Slot #<br />

Slot # 1 2 Slot # 1 2<br />

800 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

E<br />

I<br />

2<br />

E<br />

I<br />

2<br />

PPN<br />

CABINET 1<br />

PORT CARRIER<br />

PPN<br />

CABINET 1<br />

PORT CARRIER<br />

FIBER LINKS<br />

E E EPN<br />

E E<br />

EPN<br />

I I CABINET 2 I I CABINET 3<br />

CARRIER A CARRIER A